Building DWV Drainage & Soil Stacks — Engineering Master Guide

Acoustic and gravity drainage piping systems for high-rise towers, hotels, hospitals, and residential villas. SBC 702 / DIN 19531 compliant, 32 mm to 160 mm push-fit.

RFQ

Request a quotation

Direct pricing from the Jeddah plant, with technical submittal support.

ENGINEERING QUICK ANSWER

ALFA AL-ARABIA manufactures complete above-ground and in-wall uPVC Drainage, Waste, and Vent (DWV) piping systems conforming to DIN 19531, EN 1329, and the Saudi Building Code (SBC 702). Utilizing precision rubber-ring push-fit sockets and lightweight high-impact formulations, ALFA DWV systems prevent sewer gas siphonage, dampen fluid noise, and provide leak-free discharge of sanitary fixtures.

StandardDIN 19531, EN 1329-1, Saudi Building Code SBC 702
MaterialLight Grey Rigid uPVC (PVC-U)
Diameter Range32 mm, 40 mm, 50 mm, 75 mm, 110 mm, 160 mm
JointingEPDM Elastomeric Push-Fit & Solvent Cement
Max Temp60°C intermittent domestic discharge
Acoustic QualitySmooth internal flow profile minimizes structural noise

Discharge Unit (DU) Ratings & Stack Sizing per SBC 702

Calculated using primary stack ventilation system per BS EN 12056-2 / SBC 702.
Sanitary Fixture TypeDischarge Unit (DU)Min Branch Size (mm)Max Fixtures on 110mm StackMax Fixtures on 160mm Stack
Washbasin / Bidet0.5DN 32 / 40120 Units500 Units
Shower / Floor Drain0.8DN 5090 Units350 Units
Kitchen Sink / Dishwasher0.8DN 5090 Units350 Units
Commercial Washing Machine1.5DN 7550 Units200 Units
Water Closet (WC 6L Flush)2.0DN 11040 Units (approx 20 WCs)160 Units (80 WCs)

Frequently Asked Questions

Every vertical soil stack must extend full-bore through the roof to admit atmospheric air and prevent siphonage of fixture trap seals. For buildings exceeding 10 floors, secondary relief vents or parallel vent stacks are required.

A minimum 50 mm water seal depth (75 mm for high-demand commercial fixtures) is strictly required to prevent toxic sewer gases from entering living areas.

Ready to Specify ALFA Building Drainage Systems?

Contact our Jeddah engineering desk for instant project-specific pricing, technical submittals, and Material Approval Request (MAR) support.