Acoustic and gravity drainage piping systems for high-rise towers, hotels, hospitals, and residential villas. SBC 702 / DIN 19531 compliant, 32 mm to 160 mm push-fit.
Direct pricing from the Jeddah plant, with technical submittal support.
ALFA AL-ARABIA manufactures complete above-ground and in-wall uPVC Drainage, Waste, and Vent (DWV) piping systems conforming to DIN 19531, EN 1329, and the Saudi Building Code (SBC 702). Utilizing precision rubber-ring push-fit sockets and lightweight high-impact formulations, ALFA DWV systems prevent sewer gas siphonage, dampen fluid noise, and provide leak-free discharge of sanitary fixtures.
| Standard | DIN 19531, EN 1329-1, Saudi Building Code SBC 702 |
|---|---|
| Material | Light Grey Rigid uPVC (PVC-U) |
| Diameter Range | 32 mm, 40 mm, 50 mm, 75 mm, 110 mm, 160 mm |
| Jointing | EPDM Elastomeric Push-Fit & Solvent Cement |
| Max Temp | 60°C intermittent domestic discharge |
| Acoustic Quality | Smooth internal flow profile minimizes structural noise |
| Sanitary Fixture Type | Discharge Unit (DU) | Min Branch Size (mm) | Max Fixtures on 110mm Stack | Max Fixtures on 160mm Stack |
|---|---|---|---|---|
| Washbasin / Bidet | 0.5 | DN 32 / 40 | 120 Units | 500 Units |
| Shower / Floor Drain | 0.8 | DN 50 | 90 Units | 350 Units |
| Kitchen Sink / Dishwasher | 0.8 | DN 50 | 90 Units | 350 Units |
| Commercial Washing Machine | 1.5 | DN 75 | 50 Units | 200 Units |
| Water Closet (WC 6L Flush) | 2.0 | DN 110 | 40 Units (approx 20 WCs) | 160 Units (80 WCs) |
Every vertical soil stack must extend full-bore through the roof to admit atmospheric air and prevent siphonage of fixture trap seals. For buildings exceeding 10 floors, secondary relief vents or parallel vent stacks are required.
A minimum 50 mm water seal depth (75 mm for high-demand commercial fixtures) is strictly required to prevent toxic sewer gases from entering living areas.
Contact our Jeddah engineering desk for instant project-specific pricing, technical submittals, and Material Approval Request (MAR) support.